Sizes available –
WGC-25-TB – 25mm
WGC-35-TB – 35mm
WGC-55-TB – 55mm
WGC-80-TB – 80mm
WGC-110-TB – 110mm
WGC-140-TB – 140mm
WGC-180-TB – 180mm
- Description
- Additional information
- Additional Information
- Data Sheet
- More Products
- Store Policies
- Enquiries
Description
This new range presents a series of improvements above all in the installation of equipment in switchboards. Along with the usual installation fixtures, we add the possibility of doing it with a DIN rail by means of an accessory, which would facilitate its installation. The WGC series earth leakage transformers have a greater immunity to transitory type current peaks that usually cause differential protection triggers. The earth leakage transformers of the WGC Series have been designed to work with the relays of the WGC Series. The sensitivity (trigger current) of the transformer-relay set is established by the associated relay.
The earth leakage transformers of the WGC-TB series offer better immunity to the
transient current spikes that usually trigger the earth leakage protection. The earth leakage
transformers of the WGC-TB series have been designed to operate with the relays of
the WGC-TB series. The sensitivity (trip current) of the transformer-relay assembly is
established by the associated relay. Use only with RGU-10B series.
WGC-25-TB – 25mm
WGC-35-TB – 35mm
WGC-55-TB – 55mm
WGC-80-TB – 80mm
WGC-110-TB – 110mm
WGC-140-TB – 140mm
WGC-180-TB – 180mm
Additional information
Size | WGC-110 (110mm), WGC-140 (140mm), WGC-180 (180mm), WGC-220×105 (220mm x 105mm), WGC-25 (25mm), WGC-35 (35mm), WGC-350×150 (350mm x 150mm), WGC-500×200 (500mm x 200mm), WGC-55 (55mm), WGC-80 (80mm), WGC-TB110 (110mm), WGC-TB140 (140mm), WGC-TB180 (180mm), WGC-TB20 (20mm), WGC-TB25 (25mm), WGC-TB35 (35mm), WGC-TB55 (55mm), WGC-TB80 (80mm) |
---|
Technical features
Electrical insulation Safety IEC 60664-1 / IEC 60664-3
Maximum assigned service voltage 720 V
Assigned impulse voltage / pollution 3 kV / III
Measurement circuit Measurement accuracy 10…15%
Direct thermal current 6 A
Thermal short-circuit current, Ith 1.8 kA / 1 sec
Dynamic current, Idyn 2.5 Ith
Mechanical features Terminal protection IP 20 (IEC 60529)
Screw-in fasteners M-5
DIN rail (with accessory) See code
Housing material / colour Lexan 923 / RAL 7035
Self-extinguishing class UL94 V0
Product standards IEC 61869-2
Connection Two wire (S1-S2)
connection type
Screw-in terminal
(pzl screw)
Dimensions of rigid/flexible conductors 0.1…2.5 mm2
/ 27…12 AWG
Connection to
protection and
measurement devices
(RCD, RCM)
Cabling with wire section ≥ 1 mm2 0…1 m
Cabling with braided and
shielded wire section ≥ 1 mm2
0…10 m
- Add to basketQuick View
Circutor RGU-10A Earth Leakage Relay
£94.80 excl. VAT - Add to basketQuick View
Eastron RJ12 Adaptor CRJ31
£8.24 excl. VAT - Select optionsQuick View
B Meters, HD, Screwed WRAS & MID Approved Cold Water Meter
£45.00 – £57.00 excl. VATSingle jet, dry dial, direct reading on 8 numerical rolls. Produced in the
versions for cold water and hot water in the diameters DN15 and DN20
mm (1/2″- 3/4″). 360° rotating… - Select optionsQuick View
Eastron ESCT-RJ370 3 Phase EasyClick Current Transformer (70mm Center Pitch)
£31.60 – £44.42 excl. VAT - Select optionsQuick View
Eastron ESCT-RJ325 3 Phase EasyClick Current Transformer (25mm Center Pitch)
£16.95 – £19.07 excl. VAT - Add to basketQuick View
Eastron SDM630MCT-MBUS-MID Meter
£122.07 excl. VAT
General Enquiries
There are no enquiries yet.