6 x Single Phase or 2 x Three Phase, 100mA CT Operated Modbus MID Approved Meter

  • 6 x Single phase or 2 x three phase multifunction meter
  • Can monitor and display up to 4 x 3 phase 4 wire (3p4w) or 12 x single phase 2 wire (1p2w) systems
  • Allowing 128 x 3p4w circuits on a standard Modbus network
  • EasyClick technology for plug in current transformer and mains voltage connection
  • Elimination of wiring errors & labour saving
  • Designed and tested in the UK
  • Highly visible backlit display from all angles
  • Programmable reverse flow for right/left side of breaker CT installation
  • Built in Modbus and Pulsed outputs
SKU: SDM630MCT-2L MID EasyClick Category:
View basket

Description

Designed and engineered to replace the need to use 4 separate 3phase meters, monitoring and displaying each circuit from a user-friendly display. At one push of a button you can switch between each channel and from one Modbus address you can access each individual register. The SDM630MCT-ML is available in 4 different configurations:

  • SDM630MCT-1L (1 x Three Phase, or 3 x single phases)
  • SDM630MCT-2L (2 x Three Phases, or 6 x single phases)
  • SDM630MCT-3L (3 x Three Phases, or 9 x single phases)
  • SDM630MCT-4L (4 x Three Phases, or 12 x single phases)

The SDM630MCT-ML is a high accuracy multifunction power meter that has been developed with plug in connections for the current transformer and mains voltage supply inputs. This negates the need to traditional wire into the meter and saving 90% on labour as well as eliminating wiring errors. Configurable for up to 12 x single phase 2 wire (1p2w) or 4 x 3 phase 4 wire (3p4w) systems and hosting a vast range of measuring parameters such as Amps, Volts, Power, Power and Current Demand (Sliding and fix scale options), Power Factor, imported and exported kWh and total harmonics. It is one of the most user-friendly multifunction power meters in the market form installation to end client use.

It is typical in most installations that the current transformers are mounted on the left-hand side of the breaker so P1 is facing the correct way. However, it is also possible to mount the current transformer on the right-hand side with P2 facing the breaker. This is possible due to the meter having the option to reverse the flow to correct this type of application.

The SDM630MCT-ML requires mains voltage inputs and external current transformers in order to operate, The SDM630MCT-ML meter comes complete with RS485 Modbus RTU and dual pulsed outputs as standard.

Displayed Parameters

  • Phase to Neutral Voltage (V)
  • Phase Current (A)
  • Voltage Total Harmonic Distortion (U%THD)
  • Current Total Harmonic Distortion (I%THD)
  • Frequency (Hz)
  • Power Factor (PF)
  • Current Max Demand (MD A)
  • Power Max Demand (MD kW)
  • Active Power (kW)
  • Reactive Power (kVAr)
  • Apparent Power (kVA)
  • Import Active Energy (kWh)
  • Export Active Energy (kWh)
  • Total Active Energy (kWh)
  • Import Reactive Energy (kVArh)
  • Export Reactive Energy (kVArh)
  • Total Reactive Energy (kVArh)

SDM630MCT-ML_User_manual

SDM630MCT-ML

SDM630MCT-ML_Protocol

Eastron_easyclick_brochure_2020

Additional information

Brand

Eastron

Mounting

DIN Rail Mount

Certification

MID

Connection

Communication Type

CertificationMID B&D Approved
Operating temperature-25°C to +55°C
Storage temperature-40°C to +70°C
Relative humidity0 to 95%, non-condensing
AltitudeUp to 3000m
Warm up time1 minute
Vibration10Hz to 50Hz, IEC 60068-2-6, 2g
Shock30g in 3 planes
DIN rail dimensions72 x 94.5 mm (WxH) per DIN 43880
Mounting DIN rail(DIN 43880)
SealingIP51 indoor
MaterialSelf-extinguishing UL 94 V-0
Height94.5 mm
Width72 mm
Depth65 mm

 

 

 

  • EMC: EN61326-1 & EN61326-2-3
  • LVD: EN61010-1 & EN61010-2-3