Eastron Smart X96-1 MID 96×96 EasyClick Meter

0 out of 5

£111.05 excl. VAT

  • MID Certified to Class C (0.5%) accuracy
  • Designed and tested in the UK by an independent laboratory
  • 1/5A Current transformer operated
  • Individual harmonics up to 63rd level (Class 1)
  • Internal three phase power supply
  • Highly visible backlit display from all angles
  • Programmable reverse flow for right/left side of breaker CT installation.
  • Built in Modbus and Pulsed outputs
  • Free Configuration Software
SKU: SMART X96-1 MID Category:
View basket

Description

The SMART X96 series is an advanced multifunction three-phase energy monitoring solution with optional outputs such as Pulsed, RS485 RTU Modbus and Mbus. Equipped with configuration and display buttons for ease of navigation through the various parameters and settings. Housed for 96mm panel mounting, IP51 protection and 1/5A current transformer operated. Selectable measurement modes using our free configurations software for kWh display, Total kWh (Import + Export), Import kWh and Net kWh (Export – Import) Certified in the UK according to EU Directive 2014/32/EU. MID Certificate number 0120 / SGS0288.

Displayed Parameters

  • Three Phase 1/5A Current Transformer operated
  • MID B+D Certified
  • UL Registered
  • Accuracy Class 0.5 (Active Energy)
  • Bi-directional Measurement for kW and kWh
  • Configurable Pulsed output (Import/ Export / Nett kWh)
  • Modbus (SMART X96-5) or Mbus (SMART X96-5-Mbus)
  • Multi Parameter measurement
  • Phase Sequence indication
  • Phase Summary Page
  • 2nd~63rd Individual Harmonic Distortion
  • Internal three phase supply
  • Multi-Tariff
  • Free Configuration software
  • Phase to Neutral Voltage (V)
  • Phase to Phase Voltage (V)
  • Phase Current (A)
  • Individual Harmonics Amps (63rd Level)
  • Individual Harmonics Volts (63rd Level)
  • Frequency (Hz)
  • Power Factor (PF)
  • Current Max Demand (MD A)
  • Power Max Demand (MD kW)
  • Active Power (kW)
  • Reactive Power (kVAr)
  • Apparent Power (kVA)
  • Import Active Energy (kWh)
  • Export Active Energy (kWh)
  • Total Active Energy (kWh)
  • Import Reactive Energy (kVArh)
  • Export Reactive Energy (kVArh)
  • Total Reactive Energy (kVArh)
  • Phase Sequence Indication

Product Information

The Smart X96-1 is a high accuracy multifunction power meter that has been developed with plug in connections for the current transformer and mains voltage supply inputs. This negates the need to traditional wire into the meter and saving 90% on labour as well as eliminating wiring errors. Configurable for 1p2w, 3p3w and 3p4w systems and hosting a vast range of measuring parameters such as Amps, Volts, Power, Power and Current Demand (Sliding and fix scale options), Power Factor, imported and exported kWh, Individual harmonics, Phase sequence and a phase summary page. It is one of the most user-friendly multifunction power meters in the market form installation to end client use.

It is typical in most installations that the current transformers are mounted on the left-hand side of the breaker so P1 is facing the correct way. However, it is also possible to mount the current transformer on the right-hand side with P2 facing the breaker. This is possible due to the meter having the option to reverse the flow to correct this type of application.

The SMART X96-1 requires mains voltage inputs and external current transformers in order to operate, it is self-supplied via a internal three phase transformer, this means if any of the phases fail the meter will remain powered and does not require an external auxiliary supply. The Smart X96-1 meter comes complete with RS485 Modbus RTU and dual pulsed outputs as standard.

 

Additional information

Brand

Eastron

Mounting

Panel Mount

Certification

MID

Connection

,

Communication Type

Input
Nominal input voltage100-276V AC ( L-N ) 173-480V AC( L-L)
Max. continuous input overload voltage120% of nominal
Max. short duration input voltage2 x nominal voltage for 1 second
Nominal input voltage burden<0.2VA per phase
Nominal input current1/5A
Nom. Input current burden<0.1 VA
Max. continuous input overload current120% of nominal
Max. short duration input current20 x nominal current for 1 second
Power supply
Operating rangeSelf powered (from any of the three phases)
Supply burden<2W / 10 VA
Accuracy
Voltage (V)0.5% of range maximum
Current (A)0.5% of range maximum
Frequency (Hz)0.2% of mid-frequency
Power factor (PF)1% of unity (0.01)
Active power (W)1.0% of range maximum
Reactive power (VAr)1.0% of range maximum
Apparent power (VA)1.0% of range maximum
Active energy (kWh)Class 0.5S IEC62053-22

Class 1.0 IEC62053-21

Reactive energy (kVArh)1.0% of range maximum to IEC 62053-24
THD2% to 63rd harmonic
Environment
Operating temperature– 25ËšC to +55ËšC
Storage temperature-40ËšC to +70ËšC
Relative humidity0 to 95%, non-condensing
Shock30g in 3 planes
Vibration10Hz to 50Hz, IEC 60068-2-6, 2g
Dielectric Voltage4kV between voltage and current to earth
Altitude3000m
Warm-up1 minute
Outputs
Pulsed output relay (configurable)Opto-coupled, potential-free SPST-NO contact
Contact Rating current2-27mA at 27V DC
Contact Rating voltage5-27V DC
Pulse Width60 / 100 / 200 ms
Pulse rate of S0 10.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
Pulsed output of S0 2 (non-configurable)3200IMP/kWh
CommunicationsModbus RTU (RS485)
Type2-wire half duplex
Baud rate2400,4800, 9600, 19200, 38400
Address1 to 247
Enclosure
Enclosure StyleDIN 96 panel mount
Dimensions96x96x62 mm
Panel cut-out92x92mm
Panel thickness1-2 mm
Protection ratingIp51 (Indoor)
MaterialUL 94-VO
Weight340 g
Cable size0.05mm-4mm stranded wire
TerminalsVoltage: Shrouded screw-clamp. Current: RJ12.
  • MID: EN50470-1 & EN50470-3 Class B & C
  • EMC: EN61326-1 & EN61326-2-3
  • LVD: EN61010-1 & EN61010-2-3
  • IEC/EN62052-11:2003 Class 0.5s