Eastron Smart X96-1E MID 96×96 EasyClick Meter
£84.47 excl. VAT
- MID Certified to Class C (0.5%) accuracy
- EasyClick technology for plug in current transformer and mains voltage connection
- Elimination of wiring errors & labour saving
- Designed and tested in the UK by an independent laboratory
- Highly visible backlit display from all angles
- Programmable reverse flow for right/left side of breaker CT installation.
- Built in Modbus and Pulsed outputs
- Free Configuration Software
- Description
- Additional information
- Specification
- Certifications & Standards
- Vendor Info
- More Products
- Store Policies
- Enquiries
Description
Engineered and designed around a “plug and play” concept, consisting of a full range in plug in RJ12 Three phase current
transformers. This replaces the need to hardwire 6 individual secondary cables from the current transformer to the power meter. We also use a plug-in terminal for the voltage references (L1, L2, L3 and N). This not only reduces installation time by up to 85%, but also removes any potential wiring errors. Making the overall installation faster and error free.
It is also possible to have up to 32 devices powered from one voltage reference fused supply, as the meters have a voltage
output plug in terminal, allowing you to daisy chain from one meter to the next. We provide a full range of Current transformer, Voltage in and Voltage out looms. If you prefer to manufacture you own voltage looms, then this is also possible as we supply the terminal kits free of Charge with each meter.
Due to the demand of most applications requiring the power meters to be read remotely using the RS485 modbus output,
we also provide free commissioning and configuration software. This allows the modbus network to be checked prior to
installation of the panel / switchboard. It also allows you to set the programmable parameters from one central point and read each meter individually.
Displayed Parameters
- Phase to Neutral Voltage (V)
- Phase to Phase Voltage (V)
- Phase Current (A)
- Voltage Total Harmonic Distortion (U%THD)
- Current Total Harmonic Distortion (I%THD)
- Frequency (Hz)
- Power Factor (PF)
- Current Max Demand (MD A)
- Power Max Demand (MD kW)
- Active Power (kW)
- Reactive Power (kVAr)
- Apparent Power (kVA)
- Import Active Energy (kWh)
- Export Active Energy (kWh)
- Total Active Energy (kWh)
- Import Reactive Energy (kVArh)
- Export Reactive Energy (kVArh)
- Total Reactive Energy (kVArh)
Product information
The Smart X96-1E is a high accuracy multifunction power meter that has been developed with plug in connections for the current transformer and mains voltage supply inputs. This negates the need to traditional wire into the meter and saving 90% on labour as well as eliminating wiring errors. Configurable for 1p2w, and 3p4w systems and hosting a vast range of measuring parameters such as Amps, Volts, Power, Power and Current Demand, Power Factor, Imported and Exported kWh, Phase Sequence and a Phase Summary page. It is one of the most user-friendly multifunction power meters in the market form installation to end client use. The SMART X96-1E does not have the Individual harmonics, internal three phase supply (Powered from L1 & N internally), voltage output and can not be used in 3p3w applications.
It is typical in most installations that the current transformers are mounted on the left-hand side of the breaker so P1 is facing the correct way. However, it is also possible to mount the current transformer on the right-hand side with P2 facing the breaker. This is possible due to the meter having the option to reverse the flow to correct this type of application.
The SMART X96-1E requires mains voltage inputs and external current transformers in order to operate, it is self-supplied. The Smart X96-1E meter comes complete with RS485 Modbus RTU and dual pulsed outputs as standard.
Additional information
Brand | Eastron |
---|---|
Mounting | Panel Mount |
Certification | MID |
Connection | |
Communication Type |
Input | |
Nominal input voltage | 100-276V AC ( L-N ) 173-480V AC( L-L) |
Max. continuous input overload voltage | 120% of nominal |
Max. short duration input voltage | 2 x nominal voltage for 1 second |
Nominal input voltage burden | <0.2VA per phase |
Nominal input current | 1/5A |
Nom. Input current burden | <0.1 VA |
Max. continuous input overload current | 120% of nominal |
Max. short duration input current | 20 x nominal current for 1 second |
Power supply | |
Operating range | Self powered (from any of the three phases) |
Supply burden | <2W / 10 VA |
Accuracy | |
Voltage (V) | 0.5% of range maximum |
Current (A) | 0.5% of range maximum |
Frequency (Hz) | 0.2% of mid-frequency |
Power factor (PF) | 1% of unity (0.01) |
Active power (W) | 1.0% of range maximum |
Reactive power (VAr) | 1.0% of range maximum |
Apparent power (VA) | 1.0% of range maximum |
Active energy (kWh) | Class 0.5S IEC62053-22 Class 1.0 IEC62053-21 |
Reactive energy (kVArh) | 1.0% of range maximum to IEC 62053-24 |
THD | 2% to 63rd harmonic |
Environment | |
Operating temperature | – 25˚C to +55˚C |
Storage temperature | -40˚C to +70˚C |
Relative humidity | 0 to 95%, non-condensing |
Shock | 30g in 3 planes |
Vibration | 10Hz to 50Hz, IEC 60068-2-6, 2g |
Dielectric Voltage | 4kV between voltage and current to earth |
Altitude | 3000m |
Warm-up | 1 minute |
Outputs | |
Pulsed output relay (configurable) | Opto-coupled, potential-free SPST-NO contact |
Contact Rating current | 2-27mA at 27V DC |
Contact Rating voltage | 5-27V DC |
Pulse Width | 60 / 100 / 200 ms |
Pulse rate of S0 1 | 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh |
Pulsed output of S0 2 (non-configurable) | 3200IMP/kWh |
Communications | Modbus RTU (RS485) |
Type | 2-wire half duplex |
Baud rate | 2400,4800, 9600, 19200, 38400 |
Address | 1 to 247 |
Enclosure | |
Enclosure Style | DIN 96 panel mount |
Dimensions | 96x96x62 mm |
Panel cut-out | 92x92mm |
Panel thickness | 1-2 mm |
Protection rating | Ip51 (Indoor) |
Material | UL 94-VO |
Weight | 340 g |
Cable size | 0.05mm-4mm stranded wire |
Terminals | Voltage: Shrouded screw-clamp. Current: RJ12. |
- MID: EN50470-1 & EN50470-3 Class B & C
- EMC: EN61326-1 & EN61326-2-3
- LVD: EN61010-1 & EN61010-2-3
- IEC/EN62052-11:2003 Class 0.5s
Vendor Information
- Address:
- No ratings found yet!
- Select optionsQuick View
B Meters, HD, Screwed WRAS & MID Approved Cold Water Meter
£45.00 – £57.00 excl. VATSingle jet, dry dial, direct reading on 8 numerical rolls. Produced in the
versions for cold water and hot water in the diameters DN15 and DN20
mm (1/2″- 3/4″). 360° rotating… - Add to basketQuick View
Eastron RJ12 Adaptor CRJ31
£8.24 excl. VAT - Add to basketQuick View
Circutor RGU-10 Earth Leakage Relay
£71.00 excl. VATDelay: 00.2-10s on instantaneous or selective
Dimensions: 3-DIN Module
Auxillary Power supply: 230VAC (20% difference)
Output contacts: 250 Vac, 6A
Remote signal: Pre-alarm - Read moreQuick View
APHEX Meter Enclosures
Easy meter installation with pre-wired Meter Management Units
Complete metering assembly with terminal blocks, fuses and optional test terminals.
APHEX supplies an extensive range of meters mounted in a sealable rugged…
- Select optionsQuick View
B Meters, GSD8-I Screwed WRAS & MID Approved Cold Water Meter
£23.40 – £42.60 excl. VATSingle jet, dry dial, direct reading on 8 numerical rolls.
Produced in the versions for cold water and hot water
360° rotating dial.
Inductive pre-equipment for the installation of data communication modules…
- Add to basketQuick View
Circutor RGU-10A Earth Leakage Relay
£94.80 excl. VAT
General Enquiries
There are no enquiries yet.